DVR Connection N-1640MH Specifiche Pagina 52

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 83
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 51
3.11.3 NO HDD
51
WARNING SETUP MENU
FAN FAULT BUZZER ENABLE
HDD TEMP. ALARM OUTPUT 1
NO HDD ALARM DURATION PERMANENT
HDD FULL NETWORK ALARM NO
EMAIL NO
The DVR detects when both harddisks are removed, switched off or not detected. Define the
alarm reactions in this menu item:
(1) BUZZER: By selecting “ENABLE”, the buzzer is activated.
(2) ALARM OUTPUT: Output relay activation.
1 – Output relay 1 ~ 4 (selection) switches upon alarm.
NONE – no output relay reaction upon alarm.
(3) ALARM DURATION: Alarm duration adjustment from 1~99 seconds or permanent.
(4) NETWORK ALARM:
YES: Network alarm activated (for settings refer to NETWORK menu)
Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission
(5) EMAIL:
YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.
Vedere la pagina 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 82 83

Commenti su questo manuale

Nessun commento